SuperStorage SSG-927R-E2CJB 24 Hot-swap 2.5

SuperStorage SSG-927R-E2CJB 24 Hot-swap 2.5" Drive Bays shared between JBOD nodes

SuperStorage SSG-927R-E2CJB 24 Hot-swap 2.5" Drive Bays shared between JBOD nodes

    

     

SuperStorage SSG-927R-E2CJB 24 Hot-swap 2.5" Drive Bays shared between JBOD nodes

Towar dostępny na zamówienie
SKU
SSG-927R-E2CJB

SuperStorage SSG-927R-E2CJB 24 Hot-swap 2.5" Drive Bays shared between JBOD nodes

Product SKUs
SSG-927R-E2CJB
  • SuperStorage 927R-E2CJB (Black)
Add-on Module

2x AOM-SAS3-927EL-JB
Drive Bays
Hot-swap
  • 24 Hot-swap 2.5" Drive Bays shared between JBOD nodes
  • SAS drives recommended
Expander
AOM-SAS3-937EL-JB, features:
• 12Gb SAS3 HDD support
• Redundancy dual ported SAS architecture
• Robust AirMax server node connections (SBB specification)
On-Board Devices
SAS
  • SAS3 (12Gbps) via AOM-SAS3-937EL-JB
IPMI
  • Support for Intelligent Platform Management Interface v.2.0
  • IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
  • ASPEED AST2400 BMC
Front Panel
Buttons
  • Power On/Off button
LEDs
  • Power LED
  • Hard Drive Activity LED
  • 2 SAS link Activity LED
  • System Information LED
  • Power Fail LED
Chassis
Form Factor
  • 2U Rackmount
Model
  • CSE-927ETS-R0JNDBP-X10
Dimensions
Height
  • 3.5" (88mm)
Width
  • 17.2" (437mm)
Depth
  • 25.5" (648mm)
System Cooling
Fans
  • 8x 40mm cooling fans
Power Supply (76mm Width)
1200W Redundant Power Supplies with PMBus
Total Output Power
  • 1000W/1200W
Dimension
(W x H x L)
  • 76 x 40 x 336 mm
Input
  • 100-127Vac / 15-12A / 50-60Hz
  • 200-240Vac / 8.5-7A / 50-60Hz
  • 200-240Vdc / 8.5-7A (for CCC only)
+12V
  • Max: 83A / Min: 0A (100-127Vac)
  • Max: 100A / Min: 0A (200-240Vac)
  • Max: 100A / Min: 0A (200-240Vdc)
+5Vsb
  • Max: 4A / Min: 0A
Output Type
  • 19 Pairs Gold Finger Connector
Certification Titanium Level
Test Report ]
Operating Environment / Compliance
RoHS
  • RoHS Compliant
Environmental Spec.
  • Operating Temperature:
    10°C to 35°C (50°F to 95°F)
  • Non-operating Temperature:
    -40°C to 70°C (-40°F to 158°F)
  • Operating Relative Humidity:
    8% to 90% (non-condensing)
  • Non-operating Relative Humidity:
    5% to 95% (non-condensing)
Więcej informacji
rozmiar kieszeni hdd/ssd 2.5" 15mm
wspierany RAID JBOD only mode
Gwarancja 3 lata
Napisz własną recenzję
Tylko zarejestrowani użytkownicy mogą pisać Recenzje. Proszę Zaloguj się lub Załóż konto
test
Zapytaj o cenę
Trwa wysyłanie wiadomości...

Wiadomość została wysłana. Dziękujemy.

Wiadomość NIE została wysłana. Prosimy wypełnić prawidłowo wszystkie pola.
Wiadomość NIE została wysłana. Prosimy o kontakt z Działem Handlowym.
Produkt

Konfiguracja

Imię i nazwisko
Adres e-mail
Nazwa firmy
Treść wiadomości