EonStor GSa 2000 2U/24bay  all-flash-array, cloud integrated unified storage, high IOPS, dual/redundant-controller, 16GB (8GB in each controller), cache protection, super capacitor+flash, 8x 1GbE ports, 4x type-2 host board slots, drive support, SFF, 24x

EonStor GSa 2000 2U/24bay all-flash-array, cloud integrated unified storage, high IOPS, dual/redundant-controller, 16GB (8GB in each controller), cache protection, super capacitor+flash, 8x 1GbE ports, 4x type-2 host board slots, drive support, SFF, 24x

EonStor GSa 2000 2U/24bay all-flash-array, cloud integrated unified storage, high IOPS, dual/redundant-controller, 16GB (8GB in each controller), cache protection, super capacitor+flash, 8x 1GbE ports, 4x type-2 host board slots, drive support, SFF, 24x

    

     

2U/24bay all-flash-array dual/redundant-controller 16GB (8GB in each controller) super capacitor+flash host 8x 1GbE ports 4x type-2 host board slots drive support SFF, 24x drive trays

Towar dostępny na zamówienie
SKU
GSA2024RT0C0D-8B32

EonStor GSa 2000 2U/24bay all-flash-array, cloud integrated unified storage, high IOPS, dual/redundant-controller, 16GB (8GB in each controller), cache protection, super capacitor+flash, 8x 1GbE ports, 4x type-2 host board slots drive support SFF, 24x drive trays expansions 2x SAS-12G ports redundant PSU, redundant FAN and rackmount kit

Infortrend GSa all flash unified storage ma na celu zapewnienie optymalnej wydajności SSD przy niskich opóźnieniach, wydłużeniu żywotności SSD
i szerszym wyborze produktów pod względem wydajności, łączności i możliwości wyboru, aby sprostać wymaganiom współczesnego centrum danych.
GSa może obsługiwać duże ilości operacji we / wy, duży transfer plików przy dużych obciążeniach i może osiągnąć ponad 700 000 IOPS dla losowych
odczytów z czasem odpowiedzi poniżej 0,5 milisekundy.

GSa to zunifikowany system pamięci masowej, który obsługuje zarówno aplikacje blokowe, jak i pliki, i zawiera unikalną konstrukcję urządzeń blokowych Infortrend 
oraz wysoce niezawodną technologię RAID, aby zapewnić wysoką wydajność i niezawodność.


Rodzina GSa zapewnia optymalną wydajność SSD przy niskim opóźnieniu i długiej żywotności SSD, i może obsłużyć ponad 700 000 IOPS dla losowych odczytów 
z czasem odpowiedzi poniżej 0,5 milisekundy. Jest idealny do wymagających obciążeń korporacyjnych, takich jak bazy danych, wirtualizacja, VDI, Microsoft Exchange
oraz aplikacje związane z mediami / rozrywką. Zoptymalizowana wydajność SSD przy niskim opóźnieniu


Linia macierzy GSa typu all-flash została zaprojektowana bez technologii pojedynczego punktu awarii (nadmiarowy sprzęt kontrolera) w celu zapewnienia redundancji 
i obejmuje nasze ulepszone oprogramowanie wewnętrzne z funkcją Intelligent Drive Recovery (IDR) i funkcją monitorowania żywotności dysku SSD, aby zapewnić
dostępność danych. Obsługuje także mostek SAS na SATA w celu zapewnienia zgodności z opłacalnymi dyskami SSD SATA.


EonOne oferuje łatwy w obsłudze interfejs do zarządzania przez Internet, który można obsługiwać zdalnie za pośrednictwem przeglądarki internetowej, 
co zmniejsza złożoność zarządzania pamięcią masową. Intuicyjny interfejs pozwala na scentralizowane zarządzanie wieloma systemami, monitorowanie
wydajności i zużycia mocy oraz kompletowanie wszystkich konfiguracji związanych z systemem.

Features
Detailed Specifications

Model

  • GSa 2024 EonStor GSa 2000 2U/24bay  all-flash-array, cloud integrated unified storage, high IOPS

Form Factor

2U 24-bay

Controller

Dual redundant controllers

Host Ports

  • Onboard host ports
    • 8 x 1Gb/s iSCSI ports (4 per controller)
  • More host options:
    • 16 x 8Gb/s Fibre Channel ports (8 per controller)
    • 8 x 16Gb/s Fibre Channel ports (4 per controller)
    • 16 x 16Gb/s Fibre Channel ports (8 per controller, No Remote Replication support)
    • 16 x 10Gb/s FCoE ports (8 per controller)
    • 16 x 1Gb/s iSCSI ports (8 per controller)
    • 8 or 16 x 10Gb/s iSCSI ports (SFP+) (4 or 8 per controller)
    • 8 x 10Gb/s iSCSI ports (RJ-45) (4 per controller)
    • 8 x 25Gb/s iSCSI ports (SFP28) (4 per controller)
    • 8 x 40Gb/s iSCSI ports (QSFP+) (4 per controller)
    • 8 x 56Gb/s InfiniBand ports (4 per controller)—for Linux only, block level only
    • 8 x 12Gb/s SAS ports (4 per controller)
Fibre channel supports point-to-point and switch mode.

Cache Memory 

Default DDR4 16GB, up to 32GB, 64GB or 128GB

Cache Backup Techniques

Super Capacitor + Flash module

Maximum Number of Drives

  • Per system: 24
  • Via expansion enclosure: 384 and 744 (with expansion board)

Drive Connectivity

12Gb/s SAS

Drive Advanced Features

S.M.A.R.T. support/ Automatic bad-sector reassignment/ Dedicated bandwidth to each connected drive

Disk Support

  • 2.5" SATA SSD
  • 2.5" SAS SSD
For the latest compatibility details, please refer to Compatibility Matrix

Protocol Support

  • File Level Protocol
  • CIFS / SMB
  • AFP
  • NFS
  • FTP
  • FXP
  • WebDAV
  • Block Level Protocol
  • FC
  • FCoE
  • iSCSI
  • InfiniBand
  • SAS
  • Object Protocol
  • RESTful API

EonCloud Gateway

Support the integration with following cloud providers :

  • Amazon S3
  • Microsoft Azure
  • Alibaba Cloud
  • OpenStack
  • Baidu Cloud
  • Tencent Cloud

Corresponding Expansion Enclosure

Please refer to datasheet

RAID Functionality

  • Global, designated or enclosure hot-spare
  • RAID levels supported : RAID 0, 1, (1+0), 3, 5, 6, 10, 30, 50, 60
  • Online expansion by:
    • Adding new drives
    • Copying and replacing drives with drives of larger capacity
  • RAID migration
  • Configurable stripe size and write policy per system
  • Intelligent drive handling
    •  In degraded mode: skips irreparable blocks to continue rebuild
    •  In normal operation: data-block verification and repair

Data Protection and Data Service

Default software features include:

  • Thin-provisioning
  • File-level remote replication (Rsync)
  • Snapshot: 64 per volume/ 128 per system
  • Block-level local replication: Replication pairs per source volume: 4; Replication pairs per system: 16

Optional software features require additional license:

  • Advanced snapshot: 256 per volume/ 4096 per system
  • Advanced block-level local replication: Replication pairs per source volume: 8 ; Relication pairs per system: 256
  • Advanced block-level remote replicationReplication pairs per source volume: 8 ; Relication pairs per system: 64

Green Design

  • 80 PLUS-certified power supplies delivering more than 80% energy efficiency
  • Intelligent multi-level drive spin-down

Availability and Reliability

Redundant, hot-swappable hardware modules/ CacheSafe technology/ Multi-pathing support (EonPath)/ Device mapper support

Notification

Various event notification methods including email and SNMP trap. 

Management

  • Web-based EonOne management software
  • Automated cache flush and caching mode operation per enclosure status
  • Module status LED indicators: component presence detection & thermal sensors via I2C bus
  • Storage Resource Management to analyze history records of resource usage
  • Automate repeatable management tasks by flexible workflow

Network Configuration

  • IPv6 support
  • Fixed or dynamic IP address
  • Dual Gigabit Ethernet with Jumbo Frame
  • Port trunking/ NIC teaming/ Link aggregation (IEEE 802.3ad)
  • DHCP client
  • MPIO, MC/S support

Access Right Management

  • User account management
  • Group management
  • Folder management
    - Folder and subfolder access control
  • Folder quota
  • Comprehensive access control action items
    - All Controls, Read, Read and Run, Write, Modify, List
  • Support Windows Active Directory Authentication
    - Domain Users Login via CIFS/ SMB, AFP, FTP, and file explorer
  • LDAP on Linux

OS Support

Windows Server 2008 / 2008 R2 / 2012 / 2012 R2 / 2016 (including Hyper-V), Windows 7 SP1 / Windows 8.1, RedHat Enterprise Linux, CentOS, SUSE Linux Enterprise, Sun Solaris, Mac OS X, VMware, Citrix XenServer

  1. NFS protocol running on VMWare environment is currently not supported
  2. For the latest OS support details, please refer to Compatibility Matrix

Service and Support

Standard service

  • 3-year limited hardware/software warranty and 8x5 phone, web, and email support

Upgrade/Extension service (optional and service may vary by region)

  • replacement part dispatch on the next business day (up to 5 years)

Power

  • Power supplies: Redundant/hot-swappable 460W x 2
  • AC voltage: 100VAC @ 8A to 240VAC @ 4A with PFC (auto-switching)
  • Frequency: 50-60 Hz

Environmental

  • Temperature:
    • Operating: 0 to 40°C without BBU or CBM / 0 to 35°C with BBU or CBM
    • Non-operating: -40 to 60°
  • Altitude: Sea level to 3048m(10000ft) operating / sea level to 12,192m (40,000ft) non-operating
  • Relative humidity: 5 to 95% non-condensing, operating and non-operating

Regulatory

  • Safety: UL, BSMI, CB
  • Electromagnetic Compatibility: CE, BSMI, FCC

Dimensions

448mm (W) x 88mm (H) x 500mm (D)
**Without chassis ears / protrusions

Weight

17.85kg/39.35lbs(with SDDs)

Package Dimensions

780mm (W) x 340mm (H) x 580mm (D)

Więcej informacji
rozmiar kieszeni hdd/ssd 2.5" 15mm
wspierany RAID 0,1,10,5,50,6,60
Usługi danych Snapshot, Thin/Thick Clones, Thick/Thin Volumes, Read/Write Cache, Online Capacity Expansion, Encryption, Virtualization of internal storage, Thin provisioning, One-way data migration, Dual-system clustering
Gwarancja 3 lata
Napisz własną recenzję
Tylko zarejestrowani użytkownicy mogą pisać Recenzje. Proszę Zaloguj się lub Załóż konto
test
Znaleźliśmy inne produkty, które mogą Cię zainteresować!
Zapytaj o cenę
Trwa wysyłanie wiadomości...

Wiadomość została wysłana. Dziękujemy.

Wiadomość NIE została wysłana. Prosimy wypełnić prawidłowo wszystkie pola.
Wiadomość NIE została wysłana. Prosimy o kontakt z Działem Handlowym.
Produkt

Konfiguracja

Imię i nazwisko
Adres e-mail
Nazwa firmy
Treść wiadomości